2.5. General Installation Notes
£
£
£
£
£
£
£
£
£
A 400 Series system consists of two basic elements: a CENTRAL UNIT and several
CONTROL UNITS.
The CENTRAL UNIT can be placed anywhere in the system and consists in one or
more Power Supply Units a Master Unit 414A1/A2 and, optionally, several Sound
Input Units 41591/92
Tuner of 414A2 Master Unit will be defaulted to channel #1 (terminal 10).
Channel #2 (terminal 20) will be the Master Units discman/MP3/iPod input. The
additional audio channels should be connected consecutively using terminals 30,
40, ...
Master Units not equipped with tuners (414A1) will use channel #1 for the
discman/MP3/iPod input (terminal 10). The rest of audio channels should be
connected consecutively using terminals 20, 30 ...
The number of channels used should be configured on the Master Unit (see
3.14.A.Number of Audio Channels Installed).
If the room is monophonic, connect any of the speakers and set the Control Unit
to MONO (see 4.1.6.C. Control Unit Installation: Mono/Stereo).
8 ohm speakers can be connected to the Control Unit outputs. The Control Unit
must be set to 8 in this case (see 4.1.6.D. Control Unit Installation: Audio
Output).
To connect the FM antenna, connect a 76 cm wire to terminal A or connect a
75 antenna input to terminals A (signal) and M (mass).
If it is necessary to connect an amplifier or power stage to a Control Units
output, this Control Unit must be set to AMPLIFIER (see 4.1.6.D. Control Unit
Installation: Audio Output). Connect the amplifier to terminals 2, 4, 05 and 06
on the Control Unit (see )
ohm
W
Wiring Diagram Manual”
£
£
£
£
If the size of the installation requires the use of several
power supply units, the different rooms should be
divided in terms of the size of the power supplies.
Rooms are connected to 2 and 4 of each supply.
It is advisable to keep the primary line shunts as short
as possible.
Consult the manufacturer regarding installations of
over 600 meters and/or 60 Control Units.
All wire sections are 0.25 mm except supply wires
(terminals 2 and 4), which are 1 mm. The network
tapping wires are standard.
11
4
7
2
5
8
0
3
6
9
GHI
PQRS
ABC
JKL
TUV
ON
OFF
DEF
MNO
WXYZ
C FM
PGM
11
4
7
2
5
8
0
3
6
9
GHI
PQRS
ABC
JKL
TUV
ON
OFF
DEF
MNO
WXYZ
C FM
PGM
11
4
7
2
5
8
0
3
6
9
GHI
PQRS
ABC
JKL
TUV
ON
OFF
DEF
MNO
WXYZ
C FM
PGM
11
4
7
2
5
8
0
3
6
9
GHI
PQRS
ABC
JKL
TUV
ON
OFF
DEF
MNO
WXYZ
C FM
PGM
11
4
7
2
5
8
0
3
6
9
GHI
PQRS
ABC
JKL
TUV
ON
OFF
DEF
MNO
WXYZ
C FM
PGM
min. length
up to 120 Control Units
18
CC-1023ENG-10
Przeglądanie stron 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 99 100

Komentarze do niniejszej Instrukcji

Brak uwag